2011 Code of Virginia
Title 45.1 MINES AND MINING.
Chapter 14.4 Requirements Applicable to Surface Coal Mines (45.1-161.253 thru 45.1-161.292)
45.1-161.267 Fire precautions


VA Code § 45.1-161.267 (2001 through Reg Session) What's This?

45.1-161.267. Fire precautions.

A. An examination for fire shall be made after every blasting operation.

B. No person shall smoke or use an open flame within twenty-five feet of locations used to handle or store flammable or combustible liquids or where an arc or flame may cause a fire or explosion.

C. Areas surrounding flammable liquid storage tanks, electrical substations and transformers shall be kept free of combustible material for at least twenty-five feet in all directions. Such storage tanks, substations and transformers shall be posted with readily visible fire hazard warning signs.

D. Structures or areas used for storage of flammable materials shall be constructed of fire resistant material, well ventilated, kept clean and orderly and posted with readily visible fire hazard warning signs.

E. Fuel lines shall be equipped with shut-off valves at the sources. Such valves shall be readily accessible and maintained in good operating condition.

F. Battery charging areas shall be well ventilated and posted with warning signs prohibiting smoking or open flames within twenty-five feet.

G. Oil, grease, other flammable hydraulic fluid, and other flammable materials shall be kept in closed metal containers and separated from other materials so as to not create a fire hazard.

H. Combustible materials, grease, lubricants, paints and other flammable materials and liquids shall not be allowed to accumulate where they could create a fire hazard. Provision shall be made to prevent the accumulation of such material on any equipment, at storage areas and any location where the material is used.

I. Electric motors, switches, lighting fixtures, and controls shall be protected by dust-tight construction.

J. Precautions shall be taken to ensure that sparks or other hot materials do not result in a fire when welding or cutting. Welding or cutting with arc or flame shall not be done in excessively dusty atmospheres or locations. Fire-fighting apparatus shall be readily available when welding or cutting is performed.

K. Precautions shall be taken before applying heat, cutting or welding on any pipe or container that has contained a flammable or combustible material.

L. Oxygen and acetylene bottles shall be stored in racks designated and constructed for the storage of such bottles with caps in place and secured when not in use. Such bottles shall not be stored near oil, grease, and other flammable material.

M. Oxygen and acetylene gauges and regulators shall be kept clean and free of oil, grease, and other combustible materials.

N. Belt conveyors shall be equipped with control switches to automatically stop the driving motor of the conveyor in the event the belt is stopped by slipping on the driving pulley, by breakage or other accident.

O. Areas surrounding main fan installations and other mine openings shall be kept free from grass, weeds, underbrush and other combustible materials for twenty-five feet in all directions.

P. Internal combustion engines, except diesel engines, shall be shut off prior to fueling.

(Code 1950, 45-85.9; 1954, c. 191; 1966, c. 594, 45.1-39; 1978, c. 729; 1994, c. 28.)

Disclaimer: These codes may not be the most recent version. Virginia may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.