2020 Code of Virginia
Title 45.1 - Mines and Mining
Chapter 14.3 - Requirements Applicable to Underground Coal Mines
§ 45.1-161.156. (Repealed effective October 1, 2021) Slope and shaft conditions

A. All shafts shall be equipped with safety gates at the top and at each landing. Safety gates shall be kept closed except when the cage is being loaded or unloaded.

B. Positive-acting stopblocks or derails shall be installed near the top and at intermediate landings of slopes and surface inclines and at the approaches to all shaft landings.

C. Positive-acting stopblocks or derails shall be installed on the haulage track in the slope near the top of the slope. The stopblocks or derails shall be in a position to hold or stop any load, including heavy mining equipment, to be lowered into the mine until such time as the equipment is to be lowered into the mine by the hoist.

D. At the bottom of each hoisting shaft and at intermediate landings, a runaround shall be provided for safe passage from one side of the shaft to the other. This passageway shall be not less than five feet in height and three feet in width.

E. Ice shall not be permitted to accumulate excessively in any shaft where miners are hoisted or lowered.

Code 1950, § 45-68.4; 1954, c. 191; 1966, c. 594, §§ 45.1-69, 45.1-89.1; 1978, c. 729; 1983, c. 111; 1994, c. 28; 1996, c. 774; 2005, c. 3.

Disclaimer: These codes may not be the most recent version. Virginia may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.