2016 Utah Code
Title 15A - State Construction and Fire Codes Act
Chapter 6 - Additional Construction Requirements
Part 1 - Nitrogen Oxide Emission Limits for Natural Gas-fired Water Heaters
Section 102 - Nitrogen Oxide emission limits for natural gas-fired water heaters.

UT Code § 15A-6-102 (2016) What's This?
Effective 7/1/2016
15A-6-102. Nitrogen Oxide emission limits for natural gas-fired water heaters.
  • (1) As used in this section:
    • (a) "BTU" means British Thermal Unit.
    • (b)
      • (i) "Heat input" means the heat of combustion released by fuel burned in a water heater based on the heating value of the fuel.
      • (ii) "Heat input" does not include the enthalpy of a water heater's incoming combustion air.
    • (c) "Heat output" means the enthalpy of a water heater's working fluid output.
    • (d) "Natural gas-fired water heater" means a device that heats water:
      • (i) using natural gas combustion;
      • (ii) for use external to the device at a pressure that is less than or equal to 160 pounds per square inch gage; and
      • (iii) to a thermostatically controlled temperature less than or equal to:
        • (A) 210 degrees Fahrenheit; or
        • (B) 99 degrees Celsius.
    • (e) "ppm" means parts of Nitrogen Oxide per million parts of water heater air output.
    • (f) "Recreational vehicle" means the same as that term is defined in Section 13-14-102.
  • (2) Subject to Subsection (6), a person may not sell or install a natural gas-fired water heater with an emission rate greater than the following limits:
    • (a) for a water heater that has a heat input of less than or equal to 75,000 BTU per hour that is not installed in a mobile home, a limit of:
      • (i) 10 nanograms per Joule of heat output; or
      • (ii) 15 ppm, corrected to 3% oxygen;
    • (b) for a water heater that has a heat input of greater than 75,000 BTU per hour and less than 2,000,000 BTU per hour that is not installed in a mobile home, a limit of:
      • (i) 10 nanograms per Joule of heat output; or
      • (ii) 20 ppm, corrected to 3% oxygen;
    • (c) for a water heater installed in a mobile home, a limit of:
      • (i) 40 nanograms per Joule of heat output; or
      • (ii) 20 ppm, corrected to 3% oxygen;
    • (d) for a pool or spa water heater with a heat input that is less than or equal to 400,000 BTU per hour, a limit of:
      • (i) 40 nanograms per Joule of heat output; or
      • (ii) 55 ppm, corrected to 3% oxygen; and
    • (e) for a pool or spa water heater with a heat input of greater than 400,000 BTU per hour and less than 2,000,000 BTU per hour, a limit of:
      • (i) 14 nanograms per Joule of heat output; or
      • (ii) 55 ppm, corrected to 3% oxygen.
  • (3) A water heater manufacturer shall use California South Coast Air Quality Management District Method 100.1 to calculate the emissions rate of a water heater subject to this section.
  • (4) A water heater manufacturer shall display on a water heater subject to this section, as a permanent label, the model number and the Nitrogen Oxide emission rate of the water heater.
  • (5) The requirements of this section do not apply to:
    • (a) a water heater using a fuel other than natural gas;
    • (b) a water heater used in a recreational vehicle;
    • (c) a water heater manufactured in the state for sale and shipment outside of the state; or
    • (d) a water heater manufactured before July 1, 2018.
  • (6) Subsection (2) applies to the sale or installation of a water heater on or after July 1, 2018.


Enacted by Chapter 249, 2016 General Session

Disclaimer: These codes may not be the most recent version. Utah may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.