UT Code § 15A-3-313 (2012) What's This?

15A-3-313. Amendments to Chapter 13 of IPC.

(1) In IPC, Section 1301.1, all words after the word "urinals" are deleted and the following sentence is added at the end: "Gray water recycling systems for subsurface landscape irrigation shall conform with UAC R317-401 Gray Water Systems."

(2) A new IPC, Section 1301.1.1, is added as follows: "1301.1.1 Recording. The existence of a gray water recycling system shall be recorded on the deed of ownership for that property. The certificate of occupancy shall not be issued until the documentation of the recording required under this section is completed by the owner."

(3) In IPC, Section 1301.2, the words "and systems for subsurface landscape irrigation shall comply with Section 1303" are deleted.

(4) IPC, Section 1301.6, is deleted and replaced with the following: "1301.6 Potable water connections. The potable water supply to any building utilizing a gray water recycling system shall be protected against backflow by a reduced pressure backflow prevention assembly installed in accordance with Section 608."

(5) In IPC, Section 1301.7, the following is added at the end of the sentence: "and other clear water wastes which have a pH of 6.0 to 9.0; are non-flammable, non-combustible; without objectionable odor; non-highly pigmented; and will not interfere with the operation of the sewer treatment facility."

(6) In IPC, Section 1302.3, in the second sentence, the following is added between the words "backflow" and "in": "by a reduced pressure backflow prevention assembly or an air gap installed".

(7) IPC, Section 1303, is deleted and replaced with the following: "Section 1303 SUBSURFACE LANDSCAPE IRRIGATION SYSTEMS. Gray water recycling systems utilized for subsurface irrigation for single family residences shall comply with the requirements of UAC R317-401, Gray Water Systems. Gray water recycling systems utilized for subsurface irrigation for other occupancies shall comply with UAC R317-3, Design Requirements for Wastewater Collection, Treatment and Disposal and UAC R317-4, Onsite Waterwaste Systems."


Amended by Chapter 297, 2013 General Session

Disclaimer: These codes may not be the most recent version. Utah may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.