58. Cellar ceiling. The ceiling of the cellar shall be fire-retarded or be equipped with a sprinkler system, or the entire cellar shall be equipped with a fire-detecting system. Any room within the dwelling in which a boiler or furnace is used for generating heat or hot water to service the dwelling shall be enclosed with fire-retarded partitions and every door opening therefrom and its assembly shall be fireproof with the door self-closing. The ceiling of such room shall also be fire-retarded or be equipped with a sprinkler system, or the room shall be equipped with a fire-detecting system.


Disclaimer: These codes may not be the most recent version. New York may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.