2006 New York Code - Special Glasses.



 
    §  27-647  Special  glasses.  For  types  of  glass  other than single
  annealed  sheet  and  plate  glass,  allowable  maximum  areas  may   be
  determined  by  multiplying  values  in  table  10-7  by the appropriate
  multiplying factor listed in table 10-8.
 
         TABLE 10-8  Multiplying Factors for Various Types of Glass
  ========================================================================
       Glass Type                                  Multiplying Factor
  ------------------------------------------------------------------------
  Full tempered .......................................   4.0
  Heat strengthened ...................................   2.0
  Factory-fabricated double glazing ...................   1.5*
  Laminated ...........................................   0.6
  Wired ...............................................   0.5
  Sandblasted or etched ...............................   0.4
  ========================================================================
  * For asymmetrical units base strength on thinner lite.

Disclaimer: These codes may not be the most recent version. New York may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.