2006 New York Code - Structural Steel Assembly.
§ 27-1034 Structural steel assembly. (a) Placing of structural members. (1) During the placing of a structural member, the load shall not be released from the hoisting rope until the member is securely supported. (2) Open web steel joists that are hoisted singly shall be transferred from their place of storage directly to their permanent location and safely secured. No load shall be placed on open web steel joists until they are permanently fastened in place. (b) Tag lines. While structural members or assemblies are being hoisted, tag lines shall be used to prevent uncontrolled movement. (c) Erection of trusses. All trusses shall be laterally braced or guyed as necessary for the safety of the structure. (d) Erection of frames. All structural frames shall be properly braced with shores or guyed cables and turnbuckles as necessary for the safety of the structure.
Disclaimer: These codes may not be the most recent version. New York may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.