There Is a Newer Version
of
the Georgia Code
2006 Georgia Code - 8-2-90
8-2-90. As used in this part, the term:
(1) 'Fabricator' means a person who
fabricates, assembles, or glazes from component parts such
structures or products commonly known as sliding glass doors,
entrance doors, adjacent fixed glazed panels, storm doors, shower
doors, bathtub enclosures, fixed glazed panels, or other glazed
structures to be used or installed in hazardous locations.
(2)(A) 'Hazardous locations' means
for the purpose of glazing: (i) Glazing in ingress and egress doors, except
wired glass in required fire doors and jalousies;
(ii) Glazing in fixed and sliding
panels of sliding type doors (patio and mall type);
(iii) Glazing in storm doors;
(iv) Glazing in all unframed
swinging doors; (v) Glazing
in shower and bathtub doors and enclosures; (vi) Glazing, operable or inoperable, adjacent
to a door in all buildings and within the same wall plane as the
door whose nearest vertical edge is within 12 inches of the door in
a closed position and whose bottom edge is less than 60 inches
above the floor or walking surface; (vii) Glazing in fixed panels having a glazed
area in excess of nine square feet with the lowest edge less than
18 inches above the finish floor level or walking surface within 36
inches of such glazing. In lieu of safety glazing, such glazed
panels may be protected with a horizontal member not less than one
and one-half inches wide when located between 24 and 36 inches
above the walking surface; or (viii) All doors, windows, and mirrors on public
buses and trains. (B) The
following products, materials, and uses shall not be included in
the definition of the term 'hazardous locations':
(i) Openings in doors through which
a three-inch sphere is unable to pass; (ii) Leaded glass panels where no individual
piece of glass has an area greater than 30 square inches;
(iii) Glazing materials used as
curved glass panels in revolving doors; (iv) Commercial refrigerated cabinet glazed
doors; or (v) Faceted and
decorative glass. (3)
'Installer' means those persons who or those concerns which install
glazing materials or build structures containing glazing materials
in hazardous locations. (4)
'Manufacturer' means a person who manufactures safety glazing
material. (5) 'Safety glazing
material' means any glazing material, such as tempered glass,
laminated glass, wire glass, or rigid plastic, which meets the
requirements of the USA Standard Z-97.1-1966 or such requirements
as are or may be hereafter adopted by the Georgia Department of
Labor and which are constructed, treated, or combined with other
materials in such a manner as to minimize the likelihood of cutting
and piercing injuries resulting from human contact with the glazing
material.
Disclaimer: These codes may not be the most recent version. Georgia may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.