2009 California Health and Safety Code - Section 114153-114172 :: Article 3. Location And Installation

HEALTH AND SAFETY CODE
SECTION 114153-114172

114153.  Equipment for cooling and heating food and for holding cold
and hot food shall be sufficient in number and capacity to ensure
proper food temperature control during transportation and operation
as specified in Section 113996.

114157.  (a) A thermometer shall be provided for each refrigeration
unit.
   (b) The thermometer shall be located to indicate the air
temperature in the warmest part of the unit and, except for vending
machines, shall be affixed to be readily visible.
   (c) Except as specified in subdivision (d), cold or hot holding
equipment used for potentially hazardous food shall be designed to
include and shall be equipped with at least one integral or
permanently affixed temperature measuring device that is located to
allow easy viewing of the device's temperature display. Alternative
hot or cold holding equipment can be equipped with approved product
mimicking sensors placed in devices located in the warmest part of
the mechanically refrigerated unit in lieu of an ambient air sensor.
   (d) Subdivision (c) shall not apply to equipment for which the
placement of a temperature measuring device is not a practical means
for measuring the ambient air surrounding the food because of the
design, type, and use of the equipment, such as calrod units, heat
lamps, cold plates, bainmaries, steam tables, insulated food
transport containers, and salad bars.
   (e) Temperature measuring devices shall be easily readable and
have a numerical scale, printed record, or digital readout in
increments no greater than 2*F or over the intended range of use.

114159.  (a) Except for vending machines, an accurate, easily
readable, metal probe thermometer suitable for measuring the
temperature of food shall be readily available on the premises of
each food facility holding potentially hazardous food.
   (b) A food temperature measuring device with a suitable
small-diameter probe that is designed to measure the temperature of
thin masses shall be provided and readily accessible to accurately
measure the temperature in thin foods such as meat patties and fish
fillets.
   (c) Food temperature measuring devices that are scaled only in
Fahrenheit shall be accurate to +/-2*F in the intended range of use.
Food temperature measuring devices that are scaled only in Celsius or
dually scaled in Celsius and Fahrenheit shall be accurate to +/-1*C
in the intended range of use.
   (d) Food temperature measuring devices shall not have sensors or
stems constructed of glass, except that thermometers with glass
sensors or stems that are encased in a shatterproof coating, such as
candy thermometers, may be used.
   (e) Food temperature measuring devices shall be calibrated in
accordance with manufacturer's specifications as necessary to ensure
their accuracy.

114161.  (a) Except as specified in subdivision (b), equipment, a
cabinet used for the storage of food, or a cabinet that is used to
store cleaned and sanitized equipment, utensils, laundered linens,
and single-use articles shall not be in any of the following
locations:
   (1) In locker rooms.
   (2) In toilet rooms.
   (3) In refuse rooms.
   (4) In mechanical rooms.
   (5) Under sewer lines that are not shielded to intercept potential
drips.
   (6) Under leaking water lines, including leaking automatic fire
sprinkler heads, or under lines on which water has condensed.
   (7) Under open stairwells.
   (8) Under other sources of contamination.
   (b) If a mechanical clothes washer or dryer is provided, it shall
be located so that the washer or dryer is protected from
contamination and located only where there is no exposed food, clean
equipment, utensils, and linens, and unwrapped single-use articles.

114163.  (a) Except as specified in subdivision (b), all permanent
food facilities that wash, rinse, soak, thaw, or similarly prepare
foods shall be provided with a food preparation sink.
   (1) The food preparation sink shall have a minimum dimension of 18
inches by 18 inches in length and width and 12 inches in depth with
an integral drainboard or adjacent table at least 18 inches by 18
inches in length and width.
   (2) The food preparation sink shall be located in the food
preparation area, provided exclusively for food preparation, and
accessible at all times.
   (3) The sink shall be equipped with an adequate supply of hot and
cold running water through a mixing valve.
   (b) (1) Food facilities that were approved for operation without a
food preparation sink prior to January 1, 2007, need not provide a
food preparation sink unless the food facility makes a menu change or
changes their method of operation.
   (2) The enforcement officer may approve other methods where the
installation of a food preparation sink would not be readily
feasible.

114165.  Dollies, pallets, racks, and skids used to store and
transport large quantities of prepackaged foods received from a
supplier in a cased or overwrapped lot shall be designed to be moved
by hand or by conveniently available hand trucks or forklifts.

114167.   Beverage tubing and cold-plate beverage cooling devices
shall not be installed in contact with stored ice intended to be used
for food or beverages. This section shall not apply to cold plates
that are constructed integrally with an ice storage bin.

114169.  (a) Equipment that is fixed because it is not easily
movable shall be installed so that it is:
   (1) Spaced to allow access for cleaning along the sides, behind,
and above the equipment.
   (2) Spaced from adjoining equipment, walls, and ceilings a
distance of not more than one millimeter or one thirty-second inch.
   (3) Sealed to adjoining equipment or walls, if the equipment is
exposed to spillage or seepage.
   (b) Except as specified in subdivisions (c) and (d), floor-mounted
equipment that is not easily movable shall be sealed to the floor or
elevated on legs that provide at least a six-inch clearance between
the floor and the equipment.
   (c) Notwithstanding subdivision (b), this section shall not apply
to display shelving units, display refrigeration units, and display
freezer units located in the consumer shopping areas of a food
facility if the floor under the units is maintained clean.
   (d) Table-mounted equipment that is not easily movable shall be
installed to allow cleaning of the equipment and areas underneath and
around the equipment by being sealed to the table or elevated on
legs that provide at least a four-inch clearance between the table
and the equipment.

114171.  Liquid waste drain lines shall not pass through an ice
machine or ice storage bin.

114172.  All pressurized cylinders shall be securely fastened to a
rigid structure.


Disclaimer: These codes may not be the most recent version. California may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.