40 C.F.R. PART 460—HOSPITAL POINT SOURCE CATEGORY

Title 40 - Protection of Environment


Title 40: Protection of Environment

Browse Previous |  Browse Next

PART 460—HOSPITAL POINT SOURCE CATEGORY

Section Contents

Subpart A—Hospital Category

§ 460.10   Applicability; description of the hospital category.
§ 460.11   Specialized definitions.
§ 460.12   Effluent limitations and guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.


Authority:  Secs. 301, 304 (b) and (c), 360(b), 307 (b) and (c), Federal Water Pollution Control Act, as amended (33 U.S.C. 1251, 1311, 1314 (b) and (c), 1316(b) and 1317 (b) and (c), 86 Stat. 816 et seq.; Pub. L. 92–500) (the Act).

Source:  41 FR 18777, May 6, 1976, unless otherwise noted.

Subpart A—Hospital Category
top
§ 460.10   Applicability; description of the hospital category.
top

The provisions of this subpart are applicable to discharges resulting from the functional operations of the hospital point source category.

§ 460.11   Specialized definitions.
top

For the purpose of this subpart:

(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.

(b) The term “product” shall mean service resulting from the hospital activity in terms of 1,000 occupied beds.

§ 460.12   Effluent limitations and guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top

Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart, shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):

(a) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this paragraph, which may be discharged from the hospital point source subject to the provisions of this paragraph after application of the best practicable control technology currently available:

 ------------------------------------------------------------------------                                                Effluent limitations                                           -----------------------------                                                        Average of daily          Effluent characteristic             Maximum     values for 30                                             for any 1  consecutive days                                                day         shall not                                                             exceed_------------------------------------------------------------------------                                                Metric                                            units (kg/                                                 1,000                                              occupied                                                 beds)                                           -----------------------------BOD5......................................        41.0              33.6TSS.......................................        55.6              33.8pH........................................       (\1\)             (\1\)                                           -----------------------------                                               English                                            units (lb/                                                 1,000                                              occupied                                                 beds)                                           -----------------------------BOD5......................................        90.4              74.0TSS.......................................       122.4              74.5pH........................................       (\1\)             (\1\)------------------------------------------------------------------------\1\ Within the range 6.0 to 9.0.

[41 FR 18777, May 6, 1976, as amended at 60 FR 33972, June 29, 1995]

Browse Previous |  Browse Next