40 C.F.R. PART 454—GUM AND WOOD CHEMICALS MANUFACTURING POINT SOURCE CATEGORY

Title 40 - Protection of Environment


Title 40: Protection of Environment

Browse Previous |  Browse Next

PART 454—GUM AND WOOD CHEMICALS MANUFACTURING POINT SOURCE CATEGORY

Section Contents

Subpart A—Char and Charcoal Briquets Subcategory

§ 454.10   Applicability; description of the manufacture of char and charcoal briquets subcategory.
§ 454.11   Specialized definitions.
§ 454.12   Effluent limitations and guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

Subpart B—Gum Rosin and Turpentine Subcategory

§ 454.20   Applicability; description of the manufacture of gum rosin and turpentine subcategory.
§ 454.21   Specialized definitions.
§ 454.22   Effluent limitations and guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

Subpart C—Wood Rosin, Turpentine and Pine Oil Subcategory

§ 454.30   Applicability; description of the manufacture of wood rosin, turpentine and pine oil subcategory.
§ 454.31   Specialized definitions.
§ 454.32   Effluent limitations and guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

Subpart D—Tall Oil Rosin, Pitch and Fatty Acids Subcategory

§ 454.40   Applicability; description of manufacture of tall oil rosin, pitch and fatty acids subcategory.
§ 454.41   Specialized definitions.
§ 454.42   Effluent limitations and guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

Subpart E—Essential Oils Subcategory

§ 454.50   Applicability; description of the essential oils subcategory.
§ 454.51   Specialized definitions.
§ 454.52   Effluent limitations and guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.

Subpart F—Rosin-Based Derivatives Subcategory

§ 454.60   Applicability; description of manufacture of rosin-based derivatives subcategory.
§ 454.61   Specialized definitions.
§ 454.62   Effluent limitations and guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.


Authority:  Secs. 301, 304(b) and (c), 306(b), 307(b) and (c), Federal Water Pollution Control Act, as amended (33 U.S.C. 1251, 1311, 1314(b) and (c), 1316(b) and 1317(b) and (c), 86 Stat. 816 et. seq.; Pub. L. 92–500) (the Act).

Source:  41 FR 20511, May 18, 1976, unless otherwise noted.

Subpart A—Char and Charcoal Briquets Subcategory
top
§ 454.10   Applicability; description of the manufacture of char and charcoal briquets subcategory.
top

The provisions of this subpart are applicable to discharges resulting from the production of char and charcoal briquets.

§ 454.11   Specialized definitions.
top

For the purpose of this subpart:

(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.

(b) The term “product” shall mean char and charcoal briquets.

§ 454.12   Effluent limitations and guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top

Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):

(a) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this paragraph, which may be discharged from the manufacture of char and charcoal briquets by a point source subject to the provisions of this paragraph after application of the best practicable control technology currently available: There shall be no discharge of process wastewater pollutants to navigable waters.

[41 FR 20511, May 18, 1976, as amended at 60 FR 33970, June 29, 1995]

Subpart B—Gum Rosin and Turpentine Subcategory
top
§ 454.20   Applicability; description of the manufacture of gum rosin and turpentine subcategory.
top

The provisions of this subpart are applicable to discharges resulting from the manufacture of gum rosin and turpentine.

§ 454.21   Specialized definitions.
top

For the purpose of this subpart:

(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.

(b) The term “product” shall mean gum rosin and turpentine.

§ 454.22   Effluent limitations and guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top

Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):

(a) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this paragraph, which may be discharged from the manufacture of gum rosin and turpentine by a point source subject to the provisions of this paragraph after application of the best practicable control technology currently available:

[Metric units, kg/kkg of product; English units, lb/1,000 lb of product]------------------------------------------------------------------------                                                Effluent limitations                                           -----------------------------                                                        Average of daily          Effluent characteristic             Maximum     values for 30                                             for any 1  consecutive days                                                day         shall not                                                             exceed_------------------------------------------------------------------------BOD5......................................        1.42             0.755TSS.......................................       0.077             0.026pH........................................       (\1\)             (\1\)------------------------------------------------------------------------\1\ Within the range 6.0 to 9.0.

[41 FR 20511, May 18, 1976, as amended at 60 FR 33970, June 29, 1995]

Subpart C—Wood Rosin, Turpentine and Pine Oil Subcategory
top
§ 454.30   Applicability; description of the manufacture of wood rosin, turpentine and pine oil subcategory.
top

The provisions of this subpart are applicable to discharges resulting from the manufacture of wood rosin, turpentine and pine oil subcategory.

§ 454.31   Specialized definitions.
top

For the purpose of this subpart:

(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.

(b) The term “product” shall mean products from wood rosin, turpentine and pine oil.

§ 454.32   Effluent limitations and guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top

Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):

(a) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this paragraph, which may be discharged from the manufacture of wood rosin, turpentine and pine oil by a point source subject to the provisions of this paragraph after application of the best practicable control technology currently available:

[Metric units, kg/kkg of product; English units, lb/1,000 lb of product]------------------------------------------------------------------------                                                Effluent limitations                                           -----------------------------                                                        Average of daily          Effluent characteristic             Maximum     values for 30                                             for any 1  consecutive days                                                day         shall not                                                             exceed_------------------------------------------------------------------------BOD5......................................        2.08              1.10TSS.......................................        1.38             0.475pH........................................       (\1\)             (\1\)------------------------------------------------------------------------\1\ Within the range 6.0 to 9.0.

[41 FR 20511, May 18, 1976, as amended at 60 FR 33970, June 29, 1995]

Subpart D—Tall Oil Rosin, Pitch and Fatty Acids Subcategory
top
§ 454.40   Applicability; description of manufacture of tall oil rosin, pitch and fatty acids subcategory.
top

The provisions of this subpart are applicable to discharges resulting from the manufacture of tall oil rosin, pitch and fatty acids.

§ 454.41   Specialized definitions.
top

For the purpose of this subpart:

(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.

(b) The term “product” shall mean tall oil rosin, pitch and fatty acids.

§ 454.42   Effluent limitations and guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top

Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):

(a) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this paragraph, which may be discharged from the manufacture of tall oil rosin, pitch and fatty acids by a point source subject to the provisions of this paragraph after application of the best practicable control technology currently available:

[Metric units, kg/kkg of product; English units, lb/1,000 lb of product]------------------------------------------------------------------------                                                Effluent limitations                                           -----------------------------                                                        Average of daily          Effluent characteristic             Maximum     values for 30                                             for any 1  consecutive days                                                day         shall not                                                             exceed_------------------------------------------------------------------------BOD5......................................       0.995             0.529TSS.......................................       0.705             0.243pH........................................       (\1\)             (\1\)------------------------------------------------------------------------\1\ Within the range 6.0 to 9.0.

[41 FR 20511, May 18, 1976, as amended at 60 FR 33971, June 29, 1995]

Subpart E—Essential Oils Subcategory
top
§ 454.50   Applicability; description of the essential oils subcategory.
top

The provisions of this subpart are applicable to discharges resulting from the manufacture of essential oils.

§ 454.51   Specialized definitions.
top

For the purpose of this subpart:

(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.

(b) The term “product” shall mean essential oils.

§ 454.52   Effluent limitations and guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top

Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):

(a) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this paragraph, which may be discharged from the manufacture of essential oils by a point source subject to the provisions of this paragraph after application of the best practicable control technology currently available:

[Metric units, kg/kkg of product; English units, lb/1,000 lb of product]------------------------------------------------------------------------                                                Effluent limitations                                           -----------------------------                                                        Average of daily          Effluent characteristic             Maximum     values for 30                                             for any 1  consecutive days                                                day         shall not                                                             exceed_------------------------------------------------------------------------BOD5......................................        22.7              12.0TSS.......................................        9.01              3.11pH........................................       (\1\)             (\1\)------------------------------------------------------------------------\1\ Within the range 6.0 to 9.0.

[41 FR 20511, May 18, 1976, as amended at 60 FR 33971, June 29, 1995]

Subpart F—Rosin-Based Derivatives Subcategory
top
§ 454.60   Applicability; description of manufacture of rosin-based derivatives subcategory.
top

The provisions of this subpart are applicable to discharges resulting from the manufacture of rosin-based derivatives.

§ 454.61   Specialized definitions.
top

For the purpose of this subpart:

(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in 40 CFR part 401 shall apply to this subpart.

(b) The term “product” shall mean rosin-based derivatives.

§ 454.62   Effluent limitations and guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top

Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):

(a) The following limitations establish the quantity or quality of pollutants or pollutant properties, controlled by this paragraph, which may be discharged from the manufacture of rosin-based derivatives by a point source subject to the provisions of this paragraph after application of the best practicable control technology currently available:

[Metric units, kg/kkg of product; English units, lb/1,000 lb of product]------------------------------------------------------------------------                                                Effluent limitations                                           -----------------------------                                                        Average of daily          Effluent characteristic             Maximum     values for 30                                             for any 1  consecutive days                                                day         shall not                                                             exceed_------------------------------------------------------------------------BOD5......................................        1.41             0.748TSS.......................................       0.045             0.015pH........................................       (\1\)             (\1\)------------------------------------------------------------------------\1\ Within the range 6.0 to 9.0.

[41 FR 20511, May 18, 1976, as amended at 60 FR 33971, June 29, 1995]