Title 40: Protection of Environment
Browse Previous |
Browse Next
PART 443—EFFLUENT LIMITATIONS GUIDELINES FOR EXISTING SOURCES AND STANDARDS OF PERFORMANCE AND PRETREATMENT STANDARDS FOR NEW SOURCES FOR THE PAVING AND ROOFING MATERIALS (TARS AND ASPHALT) POINT SOURCE CATEGORY
Section Contents
Subpart A—Asphalt Emulsion Subcategory
§ 443.10 Applicability; description of the asphalt emulsion subcategory.
§ 443.11 Specialized definitions.
§ 443.12 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
§ 443.13 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.
§ 443.14 [Reserved]
§ 443.15 Standards of performance for new sources.
§ 443.16 Pretreatment standards for new sources.
Subpart B—Asphalt Concrete Subcategory
§ 443.20 Applicability; description of the asphalt concrete subcategory.
§ 443.21 Specialized definitions.
§ 443.22 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
§ 443.23 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.
§ 443.24 [Reserved]
§ 443.25 Standards of performance for new sources.
§ 443.26 Pretreatment standard for new sources.
Subpart C—Asphalt Roofing Subcategory
§ 443.30 Applicability; description of the asphalt roofing subcategory.
§ 443.31 Specialized definitions.
§ 443.32 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
§ 443.33 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.
§ 443.34 [Reserved]
§ 443.35 Standards of performance for new sources.
§ 443.36 Pretreatment standard for new sources.
Subpart D—Linoleum and Printed Asphalt Felt Subcategory
§ 443.40 Applicability; description of the linoleum and printed asphalt felt subcategory.
§ 443.41 Specialized definitions.
§ 443.42 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
§ 443.43 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.
§ 443.44 [Reserved]
§ 443.45 Standards of performance for new sources.
§ 443.46 Pretreatment standard for new sources.
Authority: Secs. 301, 304 (b) and (c), 306 (b) and (c) and 307(c), Federal Water Pollution Control Act, as amended (the Act); 33 U.S.C. 1251, 1311, 1314 (b) and (c), 1316 (b) and (c), 1317(c), 86 Stat. 816 et seq.; Pub. L. 92–500.
Source: 40 FR 31191, July 24, 1975, unless otherwise noted.
Subpart A—Asphalt Emulsion Subcategory
top
§ 443.10 Applicability; description of the asphalt emulsion subcategory.
top
The provisions of this subpart are applicable to discharges resulting from the production of asphalt paving and roofing emulsions.
§ 443.11 Specialized definitions.
top
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.
(b) The term “production area size” shall mean that area in which the oxidation towers, loading facilities, and all buildings that house product processes are located.
(c) The term “process wastewater pollutants” shall mean any pollutants present in the process wastewaters and rainwater runoff.
§ 443.12 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
------------------------------------------------------------------------ Effluent limitations ----------------------------- Average of daily Effluent characteristic Maximum values for 30 for any 1 consecutive days day shall not exceed_------------------------------------------------------------------------ Metric units (kg/ cu m of runoff) -----------------------------Oil and grease............................ 0.020 0.015pH........................................ (\1\) (\1\) ----------------------------- English units (lb/ 1,000 gal of runoff) -----------------------------Oil and grease............................ 0.167 0.125pH........................................ (\1\) (\1\)------------------------------------------------------------------------\1\ Within the range 6.0 to 9.0.
------------------------------------------------------------------------ Effluent limitations ----------------------------- Average of daily Effluent characteristic Maximum values for 30 for any 1 consecutive days day shall not exceed_------------------------------------------------------------------------ Metric units (kg/ cu m of runoff) -----------------------------TSS....................................... 0.023 0.015Oil and grease............................ 0.015 0.010pH........................................ (\1\) (\1\) ----------------------------- English units (lb/ 1,000 gal of runoff) -----------------------------TSS....................................... 0.188 0.125Oil and grease............................ 0.125 0.083pH........................................ (\1\) (\1\)------------------------------------------------------------------------\1\ Within the range 6.0 to 9.0.
------------------------------------------------------------------------ Effluent limitations ----------------------------- Average of daily Effluent characteristic Maximum values for 30 for any 1 consecutive days day shall not exceed_------------------------------------------------------------------------ Metric units (kg/ cu m of runoff) -----------------------------TSS....................................... 0.023 0.015Oil and grease............................ 0.015 0.010pH........................................ (\1\) (\1\) ----------------------------- English units (lb/ 1,000 gal of runoff) -----------------------------TSS....................................... 0.188 0.125Oil and grease............................ 0.125 0.083pH........................................ (\1\) (\1\)------------------------------------------------------------------------\1\ Within the range 6.0 to 9.0.
§ 443.16 Pretreatment standards for new sources.
top
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:
|
------------------------------------------------------------------------ Pollutant or pollutant property Pretreatment standard------------------------------------------------------------------------BOD5...................................... No limitation.TSS....................................... Do.pH........................................ Do.Oil and grease............................ 100 mg/l.------------------------------------------------------------------------
|
[40 FR 31191, July 24, 1975, as amended at 60 FR 33969, June 29, 1995]
Subpart B—Asphalt Concrete Subcategory
top
§ 443.20 Applicability; description of the asphalt concrete subcategory.
top
The provisions of this subpart are applicable to discharges resulting from the production of asphalt concrete.
§ 443.21 Specialized definitions.
top
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.
(b) The term “process wastewater” shall mean any water which, during the manufacturing process, comes into direct contact with any raw material, intermediate product, by-product, or product used in or resulting from the production of paving asphalt concrete.
(c) The term “process wastewater pollutants” shall mean any pollutants present in the process wastewater.
§ 443.22 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT): There shall be no discharge of process waste water pollutants to navigable waters.
[60 FR 33969, June 29, 1995]
§ 443.23 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best available technology economically achievable.
top
The following limitations establish the quantity or quality of pollutants or pollutant properties which may be discharged by a point source subject to the provisions of this subpart after application of the best available technology economically achievable: There shall be no discharge of process wastewater pollutants to navigable waters.
§ 443.24 [Reserved]
top
§ 443.25 Standards of performance for new sources.
top
The following standards of performance establish the quantity or quality of pollutants or pollutant properties which may be discharged by a new source subject to the provisions of this subpart: There shall be no discharge of process wastewater pollutants to navigable waters.
§ 443.26 Pretreatment standard for new sources.
top
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:
|
------------------------------------------------------------------------ Pollutant or pollutant property Pretreatment standard------------------------------------------------------------------------BOD5...................................... No limitation.TSS....................................... Do.pH........................................ Do.Oil and grease............................ 100 mg/l.------------------------------------------------------------------------
|
[40 FR 31191, July 24, 1975, as amended at 60 FR 33969, June 29, 1995]
Subpart C—Asphalt Roofing Subcategory
top
§ 443.30 Applicability; description of the asphalt roofing subcategory.
top
The provisions of this subpart are applicable to discharges resulting from the production of asphalt roofing materials.
§ 443.31 Specialized definitions.
top
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.
(b) The term “process wastewater” shall mean any water which, during the manufacturing process, comes into direct contact with any raw material, intermediate product, by-product, or product used in or resulting from the production of asphalt roofing materials.
(c) The term “process wastewater pollutants” shall mean any pollutants present in the process wastewater.
§ 443.32 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
|
------------------------------------------------------------------------ Effluent limitations ----------------------------- Average of daily Effluent characteristic Maximum values for 30 for any 1 consecutive days day shall not exceed_------------------------------------------------------------------------ Metric units (kg/ kkg of product) -----------------------------TSS....................................... 0.056 0.038pH........................................ (\1\) (\1\) ----------------------------- English units (lb/ 1,000 lb of product) -----------------------------TSS....................................... 0.056 0.038pH........................................ (\1\) (\1\)------------------------------------------------------------------------\1\ Within the range 6.0 to 9.0.
------------------------------------------------------------------------ Effluent limitations ----------------------------- Average of daily Effluent characteristic Maximum values for 30 for any 1 consecutive days day shall not exceed_------------------------------------------------------------------------ Metric units (kg/ kkg of product) -----------------------------TSS....................................... 0.028 0.019pH........................................ (\1\) (\1\) ----------------------------- English units (lb/ 1,000 lb of product) -----------------------------TSS....................................... 0.028 0.019pH........................................ (\1\) (\1\)------------------------------------------------------------------------\1\ Within the range 6.0 to 9.0.
------------------------------------------------------------------------ Effluent limitations ----------------------------- Average of daily Effluent characteristic Maximum values for 30 for any 1 consecutive days day shall not exceed_------------------------------------------------------------------------ Metric units (kg/ kkg of product) -----------------------------TSS....................................... 0.028 0.019pH........................................ (\1\) (\1\) ----------------------------- English units (lb/ 1,000 lb of product) -----------------------------TSS....................................... 0.028 0.019pH........................................ (\1\) (\1\)------------------------------------------------------------------------\1\ Within the range 6.0 to 9.0.
§ 443.36 Pretreatment standard for new sources.
top
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:
|
------------------------------------------------------------------------ Pollutant or pollutant property Pretreatment standard------------------------------------------------------------------------BOD5...................................... No limitation.TSS....................................... Do.pH........................................ Do.Oil and grease............................ 100 mg/l.------------------------------------------------------------------------
|
[40 FR 31191, July 24, 1975, as amended at 60 FR 33969, June 29, 1995]
Subpart D—Linoleum and Printed Asphalt Felt Subcategory
top
§ 443.40 Applicability; description of the linoleum and printed asphalt felt subcategory.
top
The provisions of this subpart are applicable to discharges resulting from the production of Linoleum and Printed Asphalt Felt floor coverings.
§ 443.41 Specialized definitions.
top
For the purpose of this subpart:
(a) Except as provided below, the general definitions, abbreviations and methods of analysis set forth in part 401 of this chapter shall apply to this subpart.
(b) The term “process wastewater” shall mean any water which, during the manufacturing process, comes into direct contact with any raw material, intermediate product, by-product, or product used in or resulting from the production of linoleum and printed asphalt felt floor coverings.
(c) The term “process wastewater pollutants” shall mean any pollutants present in the process wastewater.
§ 443.42 Effluent limitations guidelines representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available.
top
Except as provided in §§125.30 through 125.32, any existing point source subject to this subpart shall achieve the following effluent limitations representing the degree of effluent reduction attainable by the application of the best practicable control technology currently available (BPT):
|
------------------------------------------------------------------------ Effluent limitations ----------------------------- Average of daily Effluent characteristic Maximum values for 30 for any 1 consecutive days day shall not exceed_------------------------------------------------------------------------ Metric units (kg/ kkg of product) -----------------------------TSS....................................... 0.038 0.025pH........................................ (\1\) (\1\) ----------------------------- English units (lb/ 1,000 lb of product) -----------------------------TSS....................................... 0.038 0.025pH........................................ (\1\) (\1\)------------------------------------------------------------------------\1\ Within the range 6.0 to 9.0.
------------------------------------------------------------------------ Effluent limitations ----------------------------- Average of daily Effluent characteristic Maximum values for 30 for any 1 consecutive days day shall not exceed_------------------------------------------------------------------------ Metric units (kg/ kkg of product) -----------------------------TSS....................................... 0.019 0.013pH........................................ (\1\) (\1\) ----------------------------- English units (lb/ 1,000 lb of product) -----------------------------TSS....................................... 0.019 0.013pH........................................ (\1\) (\1\)------------------------------------------------------------------------\1\ Within the range 6.0 to 9.0.
------------------------------------------------------------------------ Effluent limitations ----------------------------- Average of daily Effluent characteristic Maximum values for 30 for any 1 consecutive days day shall not exceed_------------------------------------------------------------------------ Metric units (kg/ kkg of product) -----------------------------pH........................................ (\1\) (\1\) ----------------------------- English units (lb/ 1,000 lb of product) -----------------------------TSS....................................... 0.019 0.013pH........................................ (\1\) (\1\)------------------------------------------------------------------------\1\ Within the range 6.0 to 9.0.
§ 443.46 Pretreatment standard for new sources.
top
Any new source subject to this subpart that introduces process wastewater pollutants into a publicly owned treatment works must comply with 40 CFR part 403. In addition, the following pretreatment standard establishes the quantity or quality of pollutants or pollutant properties controlled by this section which may be discharged to a publicly owned treatment works by a new source subject to the provisions of this subpart:
|
------------------------------------------------------------------------ Pollutant or pollutant property Pretreatment standard------------------------------------------------------------------------BOD5...................................... No limitation.TSS....................................... Do.pH........................................ Do.Oil and grease............................ 100 mg/l.------------------------------------------------------------------------