There is a newer version of the New York Consolidated Laws
2006 New York Code - Subgrade For Footings, Foundation Piers, And Foundation Walls.
§ 27-723 Subgrade for footings, foundation piers, and foundation walls. The soil material directly underlying footings, foundation piers, and foundation walls shall be inspected by an architect or engineer after excavation and immediately prior to construction of the footings. If such inspection indicates that the soil conditions do not conform to those assumed for purposes of design and described on the plans, or are unsatisfactory due to disturbance, then additional excavation, reduction in allowable bearing pressure, or other remedial measures shall be adopted, as required. A copy of a report or reports on such inspection or inspections describing the conditions found and any necessary modification of the design, and bearing the signature of the architect or engineer making the inspections, shall be filed with the commissioner. In addition, notification shall be received by the department at least two working days prior to construction of the footing, pier, or foundation walls, that the subgrade is ready for inspection unless the requirements of section 27-209 of article twenty-one of subchapter one of this chapter have been met.
Disclaimer: These codes may not be the most recent version. New York may have more current or accurate information. We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site. Please check official sources.